Add to Cart
Fixed Gas Leakage Monitoring System Wall Mount Gas Detector With Gas Alarm Controller
Product Description
Wall Mount Central Controller for Gas Detector Fixed Gas Leakage Detection Alarm Monitoring System
Company profile
As a diversified group company, Shandong Yaoan Electronic Technology Development Co., Ltd. started to set foot in the field of gas detector in 2007, and has been deeply involved in the industry for over 16 years. we have a strong R&D team, as well as the OEM& ODM team, Our foreign company is located in Shenzhen. it takes only one hour to our airport, seaport or HK. We have around 10 oversea sales .So for different customers,we always provide with the best solutions. Covering 4 major sectors: gas detectors, gas analyzers,dust detectors, and air quality environment monitoring systems, we has over 10 branches and subsidiaries, 3 core brands Yaoan, Yaorui, Huantai.
Headquartered in Jinan(Shandong) Pilot Free Trade Zone, our production facility is over 6,000 square meters,Our products have obtained international explosion-proof certifications from ATEX,and CE,FCC,ROHS,SIL cetificatses,ensuring product quality, which are comparable to international brand like Honeywell, MSA, RAE, but our products with competitive price.
We have served more than 30,000 large and medium-sized Chinese enterprises like Sinopec, PetroChina, China Railway Group, Harbin Pharmaceutical Group, China Power Construction, etc. Besides, our products have been exported to many countries like USA, Germany, Brazil, South Korea, Russia, Italy, Japan, Korea, etc.
Product overview
YA-D400 series point type gas detectors are widely used in chemical, petroleum, metallurgy, liquefied gas stations, painting operations, gas transmission and distribution and other toxic, combustible gas generation, storage, use and other indoor and outdoor easy to leak gas dangerous places.
YA-D400 series point type gas detector is a practical and easy to operate gas detector developed by our company. It can be combined with our gas alarm controller YA-K series to form an industrial gas alarm system.The product adopts wall-mounted (can also hold the tube type, scaffolding type, ceiling type) installation, through the use of the controller, and through the controller single chip microcomputer to upload the data of the gas detector for a variety of data processing, and finally complete the data display, output control and other functions.
Specifications
Product name | YA-D400 Fixed Gas Alarm Detector |
Power supply and power | Power supply 24V; Combustible: ≤4W; Oxygen/Toxic: ≤3W |
Range | Combustible: (0-100) %LEL; Oxygen/Toxic: (0-1000) μmol/mol (determined by sensor) |
precision | ±5%FS (sensor determined) |
Minimum reading | Combustible: 1% LEL; Toxic: 0.1μmol/mol(determined by sensor) |
Response time | Toxic: ≤60 seconds; Combustible: ≤30 seconds |
Sensor life | 36 months (depending on the sensor) |
Sensor type | Combustible: catalytic combustion type; Toxic: electrochemical type (imported sensor) |
Detection mode | diffused |
Working mode | Long-term continuous work |
Connection mode | M20*15 explosion-proof hose with male thread |
Contact output | Passive contact, capacity 5A/220V (3 PCS) |
Explosion-proof mark | Ex d IIC T6 Gb/Ex tD A21 IP67 T80℃ |
Class of protection | IP67 |
Ambient temperature and humidity | Combustible: -40 ~ 70℃,15% ~ 95%RH; Toxic: -20 ~ 60℃; 15% to 95%RH |
Weight | ≤2kg |
Transmission distance | ≤1200m(RS485, 2-bus, 4-20mA only) |
Output signal | 4-20mA current signal, corresponding to full scale |
Size | 205*209*84mm |
Weight | 2Kg |
Product name | YA-K300 Gas detector control panel |
Power source | Main power supply: AC220V±15% 50~60Hz; Standby power supply: Optional |
Power | ≤15W |
Output supply voltage | DC24V±25% |
Matching detector model | YA-D series |
Number of connected detectors | Supports a maximum of eight 4-20 MA inputs and 99 RS485 data inputs 【It is recommended to use only the local power supply to connect no more than 12 sets at the same time】 |
Indication mode |
|
Alarm mode | Sound (sound pressure level at a distance of 1 meter above 70dB, 115dB below), light, voice broadcast alarm |
Response time (T90) | ≤30 seconds |
Contact output | Passive contact capacity 7A/250V (8 PCS) |
Explosion-proof mark | Non-explosion proof |
Class of protection | IP30 |
Working temperature and humidity | -20~50℃;<95%RH |
Weight | ≤5kg |
Detector and controller cable requirements | Connect the split-line detector:RVVP3×1.5mm2; Connect the 485 bus detector:RVVSP4×1.5mm2 |
Communication distance between detector and controller | ≤1200m |
Output signal | RS485,4-20mA |
Installation mode | wall-mounted |
Overall dimension | Backup battery:492*304*100mm;No backup battery:432*284*83mm |
Product Features
FAQ
1Q: What services can we provide?
A: We provide OEM/ODM service.
We provide online guidance for calibration, zero adjustment, setting, installation, etc.
2Q: Are you manufacturer or trading company?
A: We are manufacturer which has been serving since 2007.
3Q: What certificates do you have?
A: ATEX,SIL,CE, FCC, ROHS, ISO9001, etc.
4Q: What about the warranty?
A: 1 years
5Q: Do you provide after-sales technical guidance?
A: Yes, we can provide online guidance for calibration, zero adjustment, setting, installation, etc.
6Q: What about the lead time?
A: Usually 3-7 working days after payment received, but we also accept an urgent order for prompt shipment.
7Q: What's the payment method?
A: Credit card, T/T, Western Union etc.are available